1.
Clin Oral Investig ; 27(11): 6813-6821, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37796336

RESUMO

OBJECTIVES: The objectives of this study included using the cone beam computed tomography (CBCT) technology to assess: (1) intra- and inter-observer reliability of the volume measurement of the nasal cavity; (2) the accuracy of the segmentation protocol for evaluation of the nasal cavity. MATERIALS AND METHODS: This study used test-retest reliability and accuracy methods within two different population sample groups, from Eastern Asia and North America. Thirty obstructive sleep apnea (OSA) patients were randomly selected from administrative and research oral health data archived at two dental faculties in China and Canada. To assess the reliability of the protocol, two observers performed nasal cavity volume measurement twice with a 10-day interval, using Amira software (v4.1, Visage Imaging Inc., Carlsbad, CA). The accuracy study used a computerized tomography (CT) scan of an OSA patient, who was not included in the study sample, to fabricate an anthropomorphic phantom of the nasal cavity volume with known dimensions (18.9 ml, gold standard). This phantom was scanned using one NewTom 5G (QR systems, Verona, Italy) CBCT scanner. The nasal cavity was segmented based on CBCT images and converted into standard tessellation language (STL) models. The volume of the nasal cavity was measured on the acquired STL models (18.99 ± 0.066 ml). RESULTS: The intra-observer and inter-observer intraclass correlation coefficients for the volume measurement of the nasal cavity were 0.980-0.997 and 0.948-0.992 consecutively. The nasal cavity volume measurement was overestimated by 1.1%-3.1%, compared to the gold standard. CONCLUSIONS: The semi-automatic segmentation protocol of the nasal cavity in patients with sleep apnea and by using cone beam computed tomography is reliable and accurate. CLINICAL RELEVANCE: This study provides a reliable and accurate protocol for segmentation of nasal cavity, which will facilitate the clinician to analyze the images within nasoethmoidal region.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Reprodutibilidade dos Testes , Cavidade Nasal , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...